Saunier Duval Themaclassic F25 24.6 kW
230 V

Photos - Boiler Saunier Duval Themaclassic F25 24.6 kW 230 V
Outdated Product
24 552 
  
Double-circuit gas boiler with a capacity of 24.6 kW. Saunier Duval Themaclassic F25 is equipped with a closed combustion chamber, which primarily differs from the modification with the C25 index in the title. The manufacturer recommends this model for use in rooms up to 184 m2, while the capacity of the hot water system is 12 L/min at Δt=25°C. The efficiency of the installation is 92.7%, and the maximum gas flow is at the level of 2.8 m3/hour. The gas cut-off function will automatically stop the operation of the device when the flame goes out, traction is disturbed, the coolant overheats, the power supply fails, etc. It is possible to work on natural and liquefied gas, but to switch it is necessary to replace the valve and nozzles.
add to listmy lists
Saunier Duval Themaclassic F25 24.6 kW
230 V
Energy source:gas
Mount:wall, dual-circuit
Boiler power:24.6 kW, area ~ 184 m²
Combustion chamber:closed
DHW temperature:up to 65 °С

Double-circuit gas boiler with a capacity of 24.6 kW. Saunier Duval Themaclassic F25 is equipped with a closed combustion chamber, which primarily differs from the modification with the C25 index in the title. The manufacturer recommends this model for use in rooms up to 184 m2, while the capacity of the hot water system is 12 L/min at Δt=25°C. The efficiency of the installation is 92.7%, and the maximum gas flow is at the level of 2.8 m3/hour. The gas cut-off function will automatically stop the operation of the device when the flame goes out, traction is disturbed, the coolant overheats, the power supply fails, etc. It is possible to work on natural and liquefied gas, but to switch it is necessary to replace the valve and nozzles.

FAQ: 10 frequently asked questions about heating boilersAnswers to common questions in the section "heating boilers"
All specifications
Specifications Themaclassic F25
Main
Energy sourcegas
Installationwall
Typedual-circuit (heating and DHW)
Heating area184 m²
Technical specs
Heat output24.6 kW
Power supply230 V
Power consumption158 W
Coolant min. T38 °С
Coolant max. T87 °С
Heating circuit max. pressure3 bar
DHW circuit max. pressure10 bar
Consumer specs
DHW max. T65 °С
Performance (ΔT=25°C)12 L/min
Circulation pump
Boiler specs
Efficiency92.7 %
Combustion chamberclosed (turbocharged)
Inlet gas pressure20 mbar
Max. gas consumption2.77 m³/h
Expansion vessel capacity5 L
Expansion vessel pressure0.5 bar
Safety
Safety systemsgas pressure drop
water overheating
flame loss
draft control
power outage
frost protection
More specs
Dimensions (HxWxD)740х410х310 mm
Weight34 kg
Added to E-Catalogseptember 2011
FAQ: 10 frequently asked questions about heating boilersAnswers to common questions in the section "heating boilers"
Information in model description is for reference purposes.
Before buying always check characteristics and configuration of product with online store manager
Catalog Saunier Duval 2024 - new products, best sales and most actual models Saunier Duval.
anonim
9 May 2022, 09:09
Горит аворийная кнопка #
Здравствуйте
Говорит аварийная кнопка и не запускается не на воду не на отопления
Я женщина дома одна
anonim
12 November 2021, 16:00
Поднимается давление при включении отопления, а при выключении падает #
При включении давелние может подниматься выше 1.5 бар, а при выключении падает ниже 1, может упасть до 0.6 и приходится постоянно подкручивать давление. Раньше его можно было почти не трогать и подкручивать очень редко. Мастер говорит что нужно сделать профилактику. Не подскажете как решить проблему самому?
anonim
9 October 2021, 09:14
0.8 тиск і мигає, це нормально?? #
3 out of 45 question(s) shown
15 more question(s)
Model modification:
  • Model Themaclassic C25 — with an open combustion chamber
  • Model Themaclassic F25 — with closed combustion chamber

Saunier Duval Themaclassic F25 24.6 kW
230 V
price graph

Filters