Укр|Eng|Рус
Ukraine
Catalog   /   Large Appliances   /   Tumble Dryers

Comparison Bosch WTH 85077 PL vs Bosch WTW 876S0 PL

Add to comparison
Bosch WTH 85077 PL
Bosch WTW 876S0 PL
Bosch WTH 85077 PLBosch WTW 876S0 PL
Compare prices 21Compare prices 11
TOP sellers
Drying typecondensing (heat pump)condensing (heat pump)
Capacity7 kg8 kg
Drum volume112 L112 L
Features
Number of drying programmes1514
Anti-crease function
Moisture sensor
Delay start timer
Quick dry
Drum lighting
Self-cleaning heat exchanger
Drain into sewer
Condensate tank indicator
Efficiency classes
Drying classBB
Energy class
A+ /243 kWh/year/
А+++
Noise level65 dB64 dB
More specs
Controlsrotary knob + touch controlsrotary knob + touch controls
DisplayLEDLED
Child lock
Loading hatch diameter30 cm
Door shaperound with glassround with glass
Door openingrightwardrightward
Dimensions (HxWxD)84.2x59.8x66.5 cm84x60x60 cm
Color
Added to E-Catalogseptember 2023may 2018

Capacity

The maximum amount of laundry that can be loaded into the dryer; in other words, the largest weight of laundry that the machine can efficiently process in one cycle.

Capacity is usually indicated by the weight of the dry laundry. Thanks to this, when preparing the laundry for washing, you can immediately assess whether it will fit in the dryer at a time or, on the contrary, you can get by with a small drying. However, even the most modest modern dryers (and even slim ones up to 50 cm) in most cases hold 7 kg — this is comparable to loading the drum of a medium-capacity washing machine. And in the most capacious models, this figure can reach 10 – 11 kg. It is quite enough for domestic and even professional use (for example, in laundromats or laundries of hotels, etc.). However, the typical figures are drying for 8 kg and models for 9 kg of laundry. Bigger capacity is relevant for industrial equipment and is not found in consumer-level models.

Also, when choosing, note that in the specs the maximum capacity is usually indicated for linen made of cotton fabric. For other, more voluminous materials, the capacity can be noticeably less — for example, the weight limit for wool products is usually 4-5 times less than for cotton.

Number of drying programmes

The number of preset drying programmes. Such programmes are often optimized for a specific type of fabric: linen, silk, synthetics, etc. The more drying programmes, the more versatile and easier the dryer is to use. However, a specific set of modes in different models may be different, and even a large variety of programmes does not guarantee that one of them will be suitable. So before buying, it is advisable to specify not only the quantity but the list of claimed programmes.

Moisture sensor

Ability to choose the residual moisture content of the linen to be dried - from completely dry, which can be immediately put in the closet, to slightly dry, which is optimal for ironing. With laundry moisture control, the user needs to select the desired residual moisture - the dryer will automatically control the condition of the laundry and stop drying at the right time.

Drum lighting

Lighting system for the internal volume of the device. It usually turns on automatically when the dryer door is opened - thus reducing the likelihood that some items (especially small and dark ones) will be forgotten in the drum.

Self-cleaning heat exchanger

System for automatic cleaning of the heat exchanger from fibres and all kinds of deposits that prevent easy air circulation. The self-cleaning function is performed during each drying cycle. It extends the life span of the heat exchanger and ensures consistently low energy consumption over the life span of the dryer.

Drain into sewer

This option allows you to automate the process of draining the condensate collection tank (respectively, it is relevant only for dryers with a condensation principle of operation). At the end of the drying process, the condensate accumulated in the tank is automatically drained into the sewer. To do this, a pump and a hose are provided in a dryer with a drain into the sewer. The function of draining into the sewer allows you to significantly simplify the operation of the dryer, while in models without this option, the user must drain the condensate tank manually. Of course, manual emptying does not require much effort because the average condensate collection tank has a volume of about 5 litres, but still not very convenient.

Energy class

The energy consumption class shows not the actual energy consumption but the efficiency of the dryer. In other words, what part of the electricity consumed goes directly to useful work. For dryers, this parameter is especially important because such devices have high electricity consumption. As a result, models with the same capabilities but different energy efficiency classes differ markedly in terms of operating costs (in terms of electricity bills). However, more economical units themselves are more expensive. nevertheless, this difference quickly pays off.

Initially, classes were marked in Latin letters from A(the highest class) and further alphabetically. In the course of technology development, more economical levels of consumption than the original class A appeared — they are labelled as A+, A++, A+++, etc. Actually, the highest efficiency class in modern dryers is exactly A +++ ; level A — A+ can be called good, B — average, C — acceptable.

Noise level

The noise level generated by the dryer during operation. Usually, the specs indicate the maximum volume of the device, in the noisiest mode — when other programmes are running, this figure may be lower. We note that the noise level also depends on the features of the installation: for example, if the machine does not stand firmly on all four legs, vibration from drum rotation can create additional noise. And the tiled walls amplify the sound by creating an echo. Nevertheless, it is best to evaluate the device precisely by the noise level stated in the specifications. And here it is worth bearing in mind that the decibel used to denote loudness is a non-linear value, and it is best to evaluate the actual loudness of the unit using comparative tables. Here is the simplest such table for the volume range in which modern dryers operate:

65 dB — a person's voice in raised tones at a distance of 1 m;
70 dB — a loud conversation of several people at the same distance;
75 dB — loud laughter at a distance of 1 m;
80 dB — motorcycle engine, medium power vacuum cleaner.


The quieter the machine is, the more comfortable it will be to use and the better it will be suitable for a specific environment (for example, if there is a small child in the house or if you plan to run drying at night). At the same time, it is worth considering not only the actual noise level but also the installation location of the device. If the dryer is planned to...be installed in the basement of a private house with thick ceilings and the bedroom is located on the second floor, you can not pay much attention to the noise level: even the loudest unit is unlikely to create inconvenience.

Loading hatch diameter

The diameter of the loading hatch of the dryer. For models with a rectangular hatch (see “Door shape”), in this case, one of the dimensions is indicated — either width or height.

On the one hand, the larger the opening, the more convenient it is to load laundry into the machine, especially large items like bedding. On the other hand, a large hatch requires the appropriate space in front of the device — otherwise, it simply cannot be opened normally. With round openings, everything is quite simple: there should be a place in front of the drying machine corresponding to the diameter of the hatch, plus at least 3-5 centimetres in reserve. If the door is rectangular, this point is not so obvious — manufacturers can indicate the height of the opening, not the width. In such cases, it should be assumed that the door usually occupies almost the entire width of the front of the dryer. Accordingly, normal opening requires free space no less than the total width of the unit.
Price graph
Bosch WTH 85077 PL often compared
Bosch WTW 876S0 PL often compared